True Earth Installation Guide
GENERAL INFORMATION
True Earth Floorworks™ flooring can be installed quickly and easily thanks to its patented UNICLIC® system. The planks are profiled to fit precisely and lock together via the click connection. This flooring is robust, non-slip, dirt-repellent, antistatic, suitable for wet rooms and perfect for renovations.
Tools Needed
Subfloor preparation
- True Earth Floorworks™ should be installed as a floating floor.
- The substrate must be clean, dry and resistant to tension and compression.
- Do not exceed maximum height tolerance of 1/8″ across a 6′ section/
- Do not install over any type of carpeting.
- Gaps of up to 1″ can be covered with the floor
- (It is always best to fill in any gaps and prepare sublfloor to be flat.)
- Full -surface gluing to the substrate is possible.
Storage and acclimation
Product should be stored in a climate-controlled facility where warehouse temperatures are 50° F and above. When product is delivered from a climate-controlled warehouse to jobsite of 50° F or warmer, no acclimation is required. If product is kept in a facility or truck where it is exposed to cold temperatures of 40° F or lower for an extended period, product must acclimate for 24 hours at the jobsite before installation.
Inspect
Inspect planks carefully for transport damage or material defects before installation. Slight variations in color and structure are typical characteristics of the flooring and enhance the natural character. If the material or the building conditions do not meet the requirements, do not start the installation as there is no claim for replacement of installed material with visible defects.
PE foil underlayment/moisture barrier
in an environment where moisture is a concern, (Sub-grade over a new conc slab in particular) a 6mil polyethylene moisture block film vapor can be installed prior to installation. this should overlap by approximately 8 inches and be taped at the joints.
Tip: The PE foil offers additional protection against mold growth on the slab and helps with installation by making it easier to slide the joints together.
Underlayment for sound
True Earth Floorworks™ features and integrated cork underlayment for walking comfort and acoustic performance. If an additional underlayment is desired, it should have a minimum density of 25 pounds per cubic foot and be rated for use under LVT flooring to avoid potential joint failure.
Maximum room size
The maximum allowable area without additional expansion joints is 6500 s.f. (100’x 65′) per room.
Expansion space – perimeter
True Earth Floorworks™ is designed to be installed utilizing the floating method only.
- Do not secure planks to the subfloor using nails or screws.
- Do not install cabinets or fixed heavy objects on top of flooring.
- Proper expansion space of 3/8 inch at walls should be maintained to allow for potential movement of other materials in the structure.
- Undercut door jambs to allow flooring to slide underneath. NOTE: Make sure that there is sufficient space for the planks to move, especially in this area – the door frames must not stand firmly on the floor.
- Do not fasten wall moldings or transition strips to the planks to allow for potential movement.
Installation Variant 1: Angle to Angle
FIRST ROW: Start laying in right corner of the room. Lay the first plank so that the tongue side faces the wall. Align it exactly with spacer wedges. Lever the second plank with its front tongue in exact extension into the front groove of the first plank. After the first row has been precisely aligned, using a chalk line or straight edge, start laying the second row with the remaining piece of the last plank of the first row. The cross joints or end joints should ideally be offset by 8 inches or more.
SECOND ROW: The first plank of the second row is first placed at a slight angle on the long side (max. 10° / 2-3 cm) and clicked into the plank of the first row using a tapping block and hammer. The lift the second plank and the plank next to it – already clicked in – slightly (max. 10° / 2-3 cm) and then click them in lengthwise.
Lightly hit the long side of the plank and the end of the plank with a tapping block and a hammer to ensure optimal joint closure. Lay the remaining planks in direct extension of the first. Be sure to use the tapping block only on the tongue or the lower edge to prevent damage to the top decorative surface.
Installation Variant 2: Angle Snap
FIRST ROW: Start laying the right corner of the room. lay the first plank so that they tongue side faces the wall. Align it exactly with spacer wedges. place the second plank just in front of the first plank and tap it together using a tapping block and hammer. Make sure that the planks are aligned. After the first row has been precisely aligned by using a chalk line or string, start laying the second row with the remaining piece of he last plank of the first row. The cross joints or end joints should ideally be offset by 8 inches or more.
SECOND ROW: The first plank of the second row is placed at a slight angle on the longitudinal side (max. 10° / 2-3 cm) and clicked into the plank of the first row using a tapping block and hammer. on the front side, the panels are clicked into place by tapping gently with the tapping block. Lay the remaining planks in direct extension of the first.
NOTE: The spacer wedges must be removed after finishing the installation.
Door frames
When fitting around obstacles, under door jambs or into irregular spaces, planks can be cut with a jigsaw. It is often beneficial to make a cardboard template of the area and transfer this pattern to the plank. NOTE: Make sure that there is sufficient space for the planks to move, especially in this area – the door frames must not stand firmly on the floor.
Baseboards
Affix baseboards to walls and not finished floor.
Underfloor heating
Follow the instructions of the manufacturer/installer of the underfloor heating system and the relevant regulations. After the heating system has bee put into operation, the surface temperature must not exceed 82° F.
TIP: Installation on a controllable underfloor heating system is possible under the above parameters. The heating system should be a minimum of 1/16 inch under the slab.
Cleaning, care & protection
After installation, sweep, vacuum or damp mop the floor. For routine cleaning we recommend a pH-neutral cleaner. With heavy soil, use a PU cleaner. Do not use cleaners with aggressive and/or solvent – or glycerin-containing agents.
Do not add any finish to promote shine to your flooring.
In entrance areas, use dirt-trapping mats that do not cause contact discoloration. Mats with rubber or latex backing, rubber caps on equipment, chair or table legs can cause discoloration of the floor. Contact points should be protected if necessary.
Room climate